12.1 inch TFT color screen , big screen could show more information.
Screen could be rotated freely, suitable to operate in any angle and height
With heater device to prevent water into ventilator
Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or several waveform according to our operation.
Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
Curve pause function, could watch details.
Flow, pressure two trigger function, could effect at a same time.
Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
High, medium, low- grade alarm function;
Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm parameter.
Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the regulated value, turn into expiratory, ensure patient safety.
Volume security function, keep the minimum tidal volume in pressure mode.
Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal volume and minute ventilator.
VGA connector could output the screen signal to other screen
Specification
Operating Modes
Volume Control Ventilation (VCV)
Assisted/Controlled Pressure Control Ventilation (PCV),
Assisted/Controlled Pressure Support Ventilation (PSV),
SIMV(VCV)+PSV
SIMV(PCV)+PSV
Mandatory Minute Ventilation (MMV)
Continuous Positive Airway Pressure(CPAP)
Backup Apnea Ventilation
Parameter
Application scope: Pediatric and adult
Driven mode: Pneumatically driven and electronically controlled
Display:12.1 TFT screen
Working mode: Pressure and volume
Ventilation wave type: Squire wave, deceleration wave
FiO2: 21% to 100%
PEEP/CPAP: 0 to 40 cmH2O
Inspiratory Sensitivity:
Flow triggered: 0.5 to 20 L/min, OFF
Pressure triggered: -1 to -20 cmH2O, OFF
Tidal Volume: 20 to 2000 mL
Breath frequency: 1 to 100 bpm
I:E Ratio: 5.0 : 1 to 1 : 5.0
Inspiratory plateau: 0 to 50%
Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
SIGH: 1.0 to 2.0
Breath frequency(SIMV): 2 to 40bpm
Inspiratory time (SIMV): 0.1 to 12 S
Pressure Support Ventilation (PSV): 0 to 40 cmH2O
Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
Maximum Inspiratory time (PSV): 1.0 to 8.0 S
Pressure Control Ventilation(PCV): 0 to 40 cmH2O
Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
Backup Rate (PSV): 2 to 40 bpm
Object Tidal Volume(MMV): 20 to 2000 mL
Ventilation volume(MMV): 0.5 to 40.0 L/min
Nebulizer time: 30 minutes
Screen could be rotated freely, suitable to operate in any angle and height
With heater device to prevent water into ventilator
Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or several waveform according to our operation.
Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
Curve pause function, could watch details.
Flow, pressure two trigger function, could effect at a same time.
Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
High, medium, low- grade alarm function;
Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm parameter.
Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the regulated value, turn into expiratory, ensure patient safety.
Volume security function, keep the minimum tidal volume in pressure mode.
Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal volume and minute ventilator.
VGA connector could output the screen signal to other screen
Specification
Operating Modes
Volume Control Ventilation (VCV)
Assisted/Controlled Pressure Control Ventilation (PCV),
Assisted/Controlled Pressure Support Ventilation (PSV),
SIMV(VCV)+PSV
SIMV(PCV)+PSV
Mandatory Minute Ventilation (MMV)
Continuous Positive Airway Pressure(CPAP)
Backup Apnea Ventilation
Parameter
Application scope: Pediatric and adult
Driven mode: Pneumatically driven and electronically controlled
Display:12.1 TFT screen
Working mode: Pressure and volume
Ventilation wave type: Squire wave, deceleration wave
FiO2: 21% to 100%
PEEP/CPAP: 0 to 40 cmH2O
Inspiratory Sensitivity:
Flow triggered: 0.5 to 20 L/min, OFF
Pressure triggered: -1 to -20 cmH2O, OFF
Tidal Volume: 20 to 2000 mL
Breath frequency: 1 to 100 bpm
I:E Ratio: 5.0 : 1 to 1 : 5.0
Inspiratory plateau: 0 to 50%
Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
SIGH: 1.0 to 2.0
Breath frequency(SIMV): 2 to 40bpm
Inspiratory time (SIMV): 0.1 to 12 S
Pressure Support Ventilation (PSV): 0 to 40 cmH2O
Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
Maximum Inspiratory time (PSV): 1.0 to 8.0 S
Pressure Control Ventilation(PCV): 0 to 40 cmH2O
Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
Backup Rate (PSV): 2 to 40 bpm
Object Tidal Volume(MMV): 20 to 2000 mL
Ventilation volume(MMV): 0.5 to 40.0 L/min
Nebulizer time: 30 minutes